Key
This line was removed.
This word was removed. This word was added.
This line was added.
|
Changes (130)
View page history... |
| h2. Examples |
| To register a resource type named {{MyDatabase}}, use: |
| Register a resource type named {{MyDatabase}}: |
| {panel:borderStyle=solid} |
| # \# scrgadm -a -t MyDatabase |
| {panel} |
| To create a failover resource group named {{MyDatabaseRG}}, use: |
| Create a failover resource group named {{MyDatabaseRG}}: |
| {panel:borderStyle=solid} |
| # \# scrgadm -a -g MyDatabaseRG |
| {panel} |
| To create a scalable resource group named {{MyWebServerRG}}, use: |
| Create a scalable resource group named {{MyWebServerRG}}: |
| {panel:borderStyle=solid} |
| # \# scrgadm -a -g MyWebServerRG \ |
| -y Maximum_primaries=_integer_ \ -y Desired_primaries=_integer_ |
| {panel} |
| To create a resource of a given type in a resource group use the command form: |
| Create a resource of a given type in a resource group: |
| {panel:borderStyle=solid} |
| # \# scrgadm -a -j _resource-name_ -t _resource-type-name_ -g _RG-name_ |
| {panel} |
See the [rg_properties(5)|http://docs.sun.com/app/docs/doc/819-0582/6n30g7iku?l=en&a=view&q=rg_properties] man page for a description of the resource group properties. See the [r_properties(5)|http://docs.sun.com/app/docs/doc/819-0582/6n30g7ikv?l=en&a=view&q=r_properties] man page for a description of the resource properties. |
... |
| h2. {{scconf}} |
| *----- *\-\-\-\-\- Update the Sun Cluster software configuration -----* \-\-\-\-\-* |
| *Action**Object**What*{{-a }}(add){{-C }}(cluster option){{cluster=_clustername_}}{{-c }}(change){{-A }}(adapter){{add: trtype=_type_,name=_name_,node=_node_[,_other-options_] change name=_name_,node=_node_[,state=_state_][,_other-options_remove name=_name_,node=_node_}}{{-r }}(remove){{-B }}(transport junction){{add: type=_type_,name=_name_[,_other-options_] change name=_name_[,state=_state_][,_other-options_] remove name=_name_}}{{-p[vv] }}(print){{-m }}(cable endpoint){{add: endpoint=[_node_:]_name_[@_port_],endpoint=[_node_:]_name_[@_port_][,noenable] change: endpoint=[_node_:]_name_[@_port_],state=_state_ remove: endpoint=[_node_:] _name_[@_port_]}}{{-P }}(private net name){{add: node=_node_[,privatehostname=_node_[,privatehostname=_hostalias_]}}{{-q (quorum)}}{{add: globaldev=_devicename_[,node=_node_,node=_node_[,...]] change: node=_node_,{maintstate | reset} change globaldev= _devicename_,{maintstate | reset} change:resetchange: installmoderemove: globaldev=_devicename_}}{{-D }}(devicegroup){{add: type=_type_,name=_name_[,nodelist=_node_ [: _node_]...][,preferenced={true | false}][,failback={enabled | disabled}][,_otheroptions_ ] change name=_name_ [,nodelist=_node_[:_node_]...][,preferenced={true | false}][,failback={enabled | disabled}][,_other-options_ ] removename=_name_ [,nodelist=_node_[:_node_]...]}}{{-T }}(authentication){{add: node=_nodename_[,...][,authtype=_authtype_] change authtype=_authtype_ remove {node=_nodename_ [,...] | all}}}{{-h (nodes)}}{{add: node=_nodename_ remove node=_nodename or nodeID_}} |
| ||*Action*||*Object*||*What*|| |{{-a}} (add)|{{-C}} (cluster option)|{{cluster=_clustername_}}| |{{-c}} (change)|{{-A}} (adapter)|{{add: trtype=_type_,name=_name_,node=_node_\[,_other-options_\] change name=_name_,node=_node_\[,state=_state_\]\[,_other-options_remove name=_name_,node=_node_}}| |{{-r}} (remove)|{{-B}} (transport junction)|{{add: type=_type_,name=_name_\[,_other-options_\] change name=_name_\[,state=_state_\]\[,_other-options_\] remove name=_name_}}| |{{-p\[vv\]}} (print)|{{-m}} (cable endpoint)|{{add: endpoint=\[_node_:\]_name_\[@_port_\],endpoint=\[_node_:\]_name_\[@_port_\]\[,noenable\] change: endpoint=\[_node_:\]_name_\[@_port_\],state=_state_ remove: endpoint=\[_node_:\] _name_\[@_port_\]}}| | |{{-P}} (private net name)|{{add: node=_node_\[,privatehostname=_node_\[,privatehostname=_hostalias_\]}}| | |{{-q (quorum)}}|{{add: globaldev=_devicename_\[,node=_node_,node=_node_\[,...\]\] change: node=_node_,\{maintstate \| reset]} change globaldev= _devicename_,\{maintstate \| reset\} change:resetchange: installmoderemove: globaldev=_devicename_}}| | |{{-D}} (devicegroup)|{{add: type=_type_,name=_name_\[,nodelist=_node_ \[: _node_\]...\]\[,preferenced=\{true \| false\}\]\[,failback=\{enabled \| disabled\}\]\[,_otheroptions_ \] change name=_name_ \[,nodelist=_node_\[:_node_\]...\]\[,preferenced=\{true \| false\}\]\[,failback=\{enabled \| disabled\}\]\[,_other-options_ \] removename=_name_ \[,nodelist=_node_\[:_node_\]...\]}}| | |{{-T}} (authentication)|{{add: node=_nodename_\[,...\]\[,authtype=_authtype_\] change authtype=_authtype_ remove \{node=_nodename_ \[,...\] \| all\} }}| | |{{-h (nodes)}}|{{add: node=_nodename_ remove node=_nodename or nodeID_}}| |
h2. Examples |
... |
| Register a new disk group: |
| {panel:borderStyle=solid} |
| # \# scconf -a -D type=vxvm,name=new-disk-group,nodelist=nodex:nodex |
| {panel} |
| Synchronize device group information after adding a volume: |
| {panel:borderStyle=solid} |
| # \# scconf -c -D name=diskgroup,sync |
| {panel} |
Add a shared quorum device to the cluster: |
| {panel:borderStyle=solid} |
| # \# scconf -a -q globaldev=nodename |
| {panel} |
Clear "installmode": |
| {panel:borderStyle=solid} |
| # \# scconf -c -q reset |
| {panel} |
Configure a second set of cluster transport connections: |
| {panel:borderStyle=solid} |
| # \# scconf -a \ |
| -A trtype=transport,name=ifname1,node=nodename1 \ -A trtype=transport,name=ifname2,node=nodename2 \ -m endpoint=nodename1:ifname1,endpoint=nodename2:ifname2 |
| {panel} |
| Secure the cluster against other machines which that might attempt to add themselves to the cluster: |
| {panel:borderStyle=solid} |
| # \# scconf -a -T node=. |
| {panel} |
h2. {{scswitch}} |
| *----- *\-\-\-\-\- Perform ownership/state change of resource groups and disk device groups in Sun Cluster configurations -----* \-\-\-\-\-* |
| *Action**Object**Who**Special*{{-z }}(bring online){{-g }}(resource group) {{-D}} (device group){{-h }}(target host){{-h "" }}(no receiver) takes resource group offline{{-Z }}(bring everything online){{-g }}(resource group)no {{-g}} brings all resource groups online{{-F }}(take offline for all nodes){{-g }}(resource group) {{-D}} (device group){{-S }}(switch all DG and RG){{-h }}(losing host){{-K _#_}} Specifies the number of seconds to keep resource groups from switching back onto a node after that node has been successfully evacuated. Default is 60 seconds, can be set up to 65535 seconds. Starting with Sun Cluster 3.1 Update 3.{{-R }}(Restart all RG){{-h }}(target host){{-m }}(set maintenance mode){{-D }}(device group){{-u }}(unmanage RG){{-g }}(resource group){{-M }}disables monitoring only{{-o }}(online RG){{-g }}(resource group){{-M }}disables monitoring only{{-e }}(enable resource){{-j }}(resource){{-n }}(disable resource){{-j }}(resource){{-c }}(clear flag {{STOP_FAILED}}){{-j }}(resource) {{-f}} (flag name){{-h }}(target host){{-Q }}(quiesce resource group (starting in Sun Cluster 3.1 update 3)){{-g }}(resource group) |
| ||*Action*||*Object*||*Who*||*Special*|| |{{-z}} (bring online)|{{-g}} (resource group) {{-D}} (device group)|{{-h}} (target host)|{{-h ""}} (no receiver) takes resource group offline| |{{-Z}} (bring everything online)|{{-g}} (resource group)| |no {{-g}} brings all resource groups online| |{{-F}} (take offline for all nodes)|{{-g}} (resource group){{-D}} (device group)| | | |{{-S}} (switch all DG and RG)| |{{-h}} (losing host)|{{-K _#_}} specifies the number of seconds to keep resource groups from switching back onto a node after that node has been successfully evacuated. Default is 60 seconds, and can be set up to 65535 seconds. Starting with Sun Cluster 3.1 Update 3.| |{{-R}} (restart all RG)| |{{-h}} (target host)| | |{{-m}} (set maintenance mode)|{{-D}} (device group)| | | |{{-u}} (unmanage RG)|{{-g}} (resource group)| |{{-M}} disables monitoring only| |{{-o}} (online RG)|{{-g}} (resource group)| |{{-M}} disables monitoring only| |{{-e}} (enable resource)|{{-j}} (resource)| | | |{{-n}} (disable resource)|{{-j}} (resource)| | | |{{-c}} (clear flag {{STOP_FAILED}})|{{-j}} (resource) {{-f}} (flag name)|{{-h}} (target host)| | |{{-Q}} (quiesce resource group (starting in Sun Cluster 3.1 update 3))|{{-g}} (resource group)| | | |
h2. Examples |
... |
| Switch over _resource-grp-2_ to be mastered by _node1:_ |
| {panel:borderStyle=solid} |
| # \# scswitch -z -h node1 -g resource-grp-2 |
| {panel} |
Switch over _resource-grp-3_, a resource group configured to have multiple primaries, to be mastered by _node1_, _node2_, _node3_: |
| {panel:borderStyle=solid} |
| # \# scswitch -z -h node1,node2,node3 -g resource-grp-3 |
| {panel} |
Switch all managed resource groups online on their most _preferred_ node or nodes: |
| {panel:borderStyle=solid} |
| # \# scswitch -z |
| {panel} |
Quiesce _resource-grp-2_. Stops RG from _continuously_ bouncing around from one node to another in the event of the failure of a {{START}} or {{STOP}} method: |
| {panel:borderStyle=solid} |
| # \# scswitch -Q -g resource-group-2 |
| {panel} |
Switch over all resource groups and disk device groups from _node1_ to a new set of primaries: |
| {panel:borderStyle=solid} |
| # \# scswitch -S -h node1 |
| {panel} |
Restart some resource groups on specified nodes: |
| {panel:borderStyle=solid} |
| node1\# scswitch -R -h node1,node2 -g resource-grp-1,resource-grp-2 |
| {panel} |
Disable some resources: |
| {panel:borderStyle=solid} |
| # \# scswitch -n -j resource-1,resource-2 |
| {panel} |
Enable a resource: |
| {panel:borderStyle=solid} |
| # \# scswitch -e -j resource-1 |
| {panel} |
Take resource groups to the unmanaged state: |
| {panel:borderStyle=solid} |
| # \# scswitch -u -g resource-grp-1,resource-grp-2 |
| {panel} |
Take resource groups to the online state: |
| {panel:borderStyle=solid} |
| # \# scswitch -o -g resource-grp-1,resource-grp-2 |
| {panel} |
Switch over _device-group-1_ to be mastered by _node2:_ |
| {panel:borderStyle=solid} |
| # \# scswitch -z -h node2 -D device-group-1 |
| {panel} |
Put _device-group-1_ into maintenance mode: |
| {panel:borderStyle=solid} |
| # \# scswitch -m -D device-group-1 |
| {panel} |
Move all resource groups and disk device groups persistently off of a node: |
| # scswitch -S -h iloveuamaya -K 120 This situation arises when resource groups attempt to switch back automatically when strong negative affinities have been configured (with {{RG_affinities}}). |
| {panel:borderStyle=solid} \# scswitch -S -h iloveuamaya -K 120 {panel} |
| This situation arises when resource groups attempt to switch back automatically when strong negative affinities have been configured (with {{RG_affinities}}). |
| h2. {{scstat}} |
| *----- *\-\-\-\-\- Monitor the status of Sun Cluster -----* \-\-\-\-\-* |
| *Action**Options*{{-D }}(shows status for all disk groups){{-g }}(shows status for all resource groups){{-h host }}(show status of all components related to specified host){{-i }}(shows status for all IPMP groups and public network adapters){{-n }}(shows status for all nodes){{-h host }}(shows status for the specified node){{-p }}(shows status for all components in the cluster){{-v[v] }}verbose output{{-q }}(shows status for all device quorums and node quorums){{-W }}(shows status for cluster transport path) |
| ||*Action*||*Options*|| |{{-D}} (shows status for all disk groups)| | |{{-g}} (shows status for all resource groups)|{{-h host}} (show status of all components related to specified host)| |{{-i}} (shows status for all IPMP groups and public network adapters)| | |{{-n}} (shows status for all nodes)| | |{{-h host}} (shows status for the specified node)| | |{{-p}} (shows status for all components in the cluster)|{{-v\[v\]}} verbose output| |{{-q}} (shows status for all device quorums and node quorums)| | |{{-W}} (shows status for cluster transport path)| | |
h2. Examples |
... |
| Show status of all resource groups followed by the status of all components related to node1: |
| # scstat -g -h node1 or # scstat -g and # scstat -h node1 |
| {panel:borderStyle=solid} \# scstat -g -h node1 {panel} |
| h2. {{scdpm}} |
| or: |
| Available in Sun Cluster 3.1 update 3. |
| {panel:borderStyle=solid} \# scstat -g {panel} |
| *----- Disk-path monitoring administration command -----* |
| and |
| *Action**What*{{-m }}(Monitor the new disk path that is specified by node:disk path. All is default option) |
| {panel:borderStyle=solid} \# scstat -h node1 {panel} |
| {{[node]}} |
| h2. {{scdpm}} |
| [node:all] |
| Available starting in Sun Cluster 3.1 update 3. |
| [node:/dev/dis/rdsk/d-] |
| *\-\-\-\-\- Disk-path monitoring administration command \-\-\-\-\-* |
| ||*Action*||*What*|| |{{-m}} (monitor the new disk path that is specified by node:disk path. All is default option)|{{\[node\]}} \\ \[node:all\] \\ \[node:/dev/dis/rdsk/d-\]| |
| {{-u }}(Unmonitor |{{-u}} (unmonitor a disk path. The daemon on each node stops monitoring the specified path. All is default option)|{{\[node\]}} \\ \[node:all\] \\ \[node:/dev/dis/rdsk/d-\]| |
| |{{-p \[-F\]}} (print current status of a specified disk path from all the nodes that are attached to the storage. All is default option. The {{-F}} option prints only faulty disk paths)|{{\[node\]}} \\ \[node:all\] \\ \[node:/dev/dis/rdsk/d-\]| |{{-f filename}} (read the list of disk paths to monitor or unmonitor for a specified file name.)| | |
| {{[node]}} |
| h2. Examples |
| [node:all] |
| Force daemon to monitor all disk paths in the cluster infrastructure: |
| [node:/dev/dis/rdsk/d-] |
| {panel:borderStyle=solid} \# scdpm -m all {panel} |
| {{-p [-F] }}(Print current status of a specified disk path from all the nodes that are attached to the storage. All is default option. The {{-F}} option prints only faulty disk paths) |
| Monitor a new path on all nodes where path is valid: |
| {{[node]}} |
| {panel:borderStyle=solid} \# scdpm -m /dev/did/dsk/d3 {panel} |
| [node:all] |
| Monitor new paths on just {{node1}}: |
| [node:/dev/dis/rdsk/d-] |
| {panel:borderStyle=solid} \# scdpm -m node1:d4 -m node1:d5 {panel} |
| {{-f filename }}(Read the list of disk paths to monitor or unmonitor for a specified file name.) |
| Print all disk paths in the cluster and their status: |
| h2. Examples |
| {panel:borderStyle=solid} \# scdpm -p all:all {panel} |
| Force daemon to monitor all disk paths in the cluster infrastructure: |
| Print all failed disk paths: |
| # scdpm -m all Monitor a new path on all nodes where path is valid: # scdpm -m /dev/did/dsk/d3 Monitor new paths on just node1 #scdpm -m node1:d4 -m node1:d5 Print all disk paths in the cluster and their status: # scdpm -p all:all Print all failed disk paths # scdpm -p -F all Print the status of all disk paths from node1: # scdpm -p node1:all |
| {panel:borderStyle=solid} \# scdpm -p -F all {panel} |
| Print the status of all disk paths from {{node1}}: {panel:borderStyle=solid} \# scdpm -p node1:all {panel} |
| h2. Covered Products |
... |